Char-Broil 4885637 - Wireless Multi-Sensor Meat Thermometer Manual
Please keep this manual for o peration instructions and for future reference.
OVERVIEW
FRONT VIEW
- POWER: Power ON / OFF - Backlight ON / OFF
- MEAT: Select meat type
- PROBE / CF: Select probe tip or cold spot / change between °C and °F
- TASTE: S et Target Temperature
- START / STOP: Timer Start/Stop
- MIN/ UP: Timer Minutes / Scroll Up
- SEC/ DOWN: Timer Seconds / Scroll Down
- CLEAR / ALARM: Clear entry / Alarm Silence
BACK VIEW
- Removable Belt Clip
- Battery Compartment
- Transmitter ON/OFF
- Transmitter Jack
LCD SCREEN
- Meat Type
- Target Temperature
- Countdown Timer
- Remaining Time
- Alarm ON icon
- Sensor selection Icon
- Current temperature
TRANSMITTER AND PROBE
- Battery Compartment
- Connector jack for probe
- POWER: ON / OFF
- Probe Connector
- Multi-Sensor Probe
- "Cold Spot" mark
GETTING STARTED
BATTERIES
Insert the batteries as shown, taking care to match the polarities (+ / -). Insert batteries into both receiver and transmitter.
TRANSMITTER DATA TRANSMISSION
Place the transmitter within 100 Feet of the handheld unit.
OPERATION
he probe is a sharp metal object, and will become hot during cooking. Take care when handling.
- Plug the probe connector to the transmitter jack.
- Insert tip of the probe into the center of the meat, taking care not to pierce through it. Do not expose any part of the probe or cable to open fl ames.
- The probe contains 5 separate sensors spaced along the probe beginning at the tip. If utilizing the "Cold Spot" function, make sure probe is fully inserted up to the "Cold Spot" mark indicated on the probe.
- Press the POWER button on both transmitter and handheld receiver.
- Press the MEAT button on handheld receiver to select the type of meat that you are cooking. Each press of the button will cycle through the selections. BEEF - LAMB - PORK - POULTRY (PLTRY) - GROUND BEEF/LAMB (HMBGR) - OTHER
- Press the TASTE button on handheld receiver to select the doneness of meat that you desire. Each press of the button will cycle through the selections. RARE - MED. RARE - MED - MED. WELL - WELL.
NOTE - if you select meat type "OTHER" you can set the desired internal temperature manually. The default temperature is 150°F. Press the UP/DOWN buttons to set the desired target temperatures. The selectable range is 110°F to 250°F.
- Set the Timer - Press the MIN or SEC button on handheld receiver to select the desired cooking time.
NOTE - if you hold the button for more than 10 seconds, the digits will increase/decrease rapidly. To reset the time, press the CLEAR button.
- Set the Alarm - Press and hold the ALARM button on handheld receiver for 3 seconds to select Alarm ON or OFF. The icon will display when the alarm is active. Once the food has reached the target temperature. The will flash and an alarm beep will sound.
- Set the Probe Mode.
Probe Function: The display can be set to "Tip" or "Coldspot". To use the probe in "TIP" mode, press the "PROBE" button until "Tip" shows in the display. This function will display the temperature sensed by the Tip sensor of the probe. Press the "PROBE" button again to switch to the "Coldspot" function. This function will scan each of the sensors in the probe and display the coldest reading.
MANUALLY SET TARGET TEMPERATURE
- Insert probe into the meat as described in "OPERATION" section.
- Press and hold MODE to select manual target temperature mode. When in this mode, the meat icons will disappear.
- Press MEAT / UP and COOK / DOWN to select your desired temperature.
- Your target temperature will appear on the LCD screen. Begin cooking.
- The cooking alerts will sound as described above.
- Press any button to silence the alert.
NOTE Press and hold MODE to return to automatic target temperature mode.
ALARM INDICATIONS
- Once the meat probe has reached the desired internal temperature, a loud beeping alarm will sound and the symbol will flash. The audible signal will be two beeps with one second of silence between beeps.
- Press "STOP" to silence the alarm signal. Note that the symbol will continue to flash unless current temperature is below target temperature. The Alarm signal will silence itself after 30 seconds if the STOP button is not pressed.
- If the current temperature falls below the target temperature, the alarm will silence itself.
COUNT-UP / COUNTDOWN TIMER
The count-up and countdown timers operate independently of the temperature probe sensors.
To set a count-up timer:
If no countdown time is set the timer will act as a count up timer.
To start timer:
- Press START / STOP to begin.
- Press START / STOP again to pause,
- Once paused, press CLEAR to reset to zero.
- Once a countdown has fi nished, the unit will beep 4 times repeatedly until you press the STOP button.
The timer display will also flash.
The alert will silence itself after 30 seconds.
NOTE The countdown timer will count up to 23:59.59 sec.
To set a countdown time:
Use MIN and SEC to set the countdown time. To start timer:
- Press START / STOP to begin.
- Press START / STOP again to pause,
- Once paused, press CLEAR to reset to zero.
- Once a countdown has fi nished, the unit will beep 4 times repeatedly until you press the STOP button.
The timer display will also flash.
The alert will silence itself after 30 seconds.
AFTER COOKING
- Once cooking is fi nished, remove the probe using an oven mitt.
- Clean the probe with water and a mild detergent. To clean the main unit and sensor, wipe with a damp cloth.
NOTE: Do not clean the probe in a dishwasher or immerse the main unit or sensor in water.
TEMPERATURE UNITS
Press C / F to select the preferred temperature units.
NOTE When the probe temperature exceeds the maximum display temperature (310°C / 610°F) the LCD will show "HHH". When the probe temperature is below the minimum display temperature (-10°C / 14°F) the LCD will show "LLL".
BACKLIGHT
Press the Power button to illuminate the screen for 10 seconds.
PRECAUTIONS
- Do not subject the unit to excessive force, shock, dust, temperature or humidity.
- Do not cover the ventilation holes with any items such as newspapers, curtains etc.
- Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.
- Do not clean the unit with abrasive or corrosive materials.
- Do not attempt to service this unit.
There are no user serviceable components.
- Only use fresh batteries. Do not mix new and old batteries.
- Properly dispose of old batteries. be sure to Recycle old batteries.
- Do not place unit in dishwasher. old batteries.
NOTE The technical specifi cations for this product and the contents of the user manual are subject to change without notice.
SPECIFICATIONS
TYPE | DESCRIPTION |
HANDHELD RECEIVER UNIT |
L x W x H | 120 x 60 x 26.5 mm (4.72 x 2.36 x 1.04 in) |
Weight (without batteries) | 75g (2.6 oz) |
Temperature unit | °C / °F |
Temperature Accuracy | 1.6°C (3°F) (70°F - 210°F) |
Display temperature range | -10°C - 321°C (14°F - 610°F) |
Signal frequency | 915MHz |
Power | 2 x UM-4 AAA 1.5 V batteries |
BASE TRANSMITTER UNIT |
L x W x H | 70 x 91 x 56 mm (2.7 x 3.6 x 2.2 in) |
Weight (without batteries) | 50 g (1.75 oz) |
Transmission range | 33 m (100 ft) unobstructed |
Power | 2 x UM-4 AAA 1.5V batteries |
Documents / Resources
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Need Assistance?
Do you have a question about the 4885637 that isn't answered in the manual? Leave your question here.